HVAC
Image 1
Image 2
Image 3
Image 3

Description


Wall Mounted HVAC
Heating and Air Conditioning Units 

At Steam Equipments, we offer reliable and high-performance Heating, Ventilation, and Air Conditioning (HVAC) solutions through our association with Bard, a global leader in climate control technology. Bard’s HVAC systems are designed to deliver efficient, durable, and cost-effective environmental control for a wide range of industrial, commercial, and institutional applications.

Bard’s wall-mounted, packaged, and split-system units are known for their robust construction, easy installation, and low maintenance. These systems ensure precise temperature regulation and air quality management, even under demanding operating conditions. With advanced technology for energy efficiency, quiet operation, and long service life, Bard HVAC units are ideal for data centers, telecom shelters, schools, control rooms, and other critical environments. 

Our collaboration with Bard enables us to provide customized HVAC solutions that meet diverse client requirements while ensuring optimal performance and reliability. Steam Equipments also offers complete support — from system selection and design to installation, commissioning, and after-sales service — ensuring seamless operation and maximum uptime.

Bard Manufacturing Company, Inc. is a globally recognized leader in the design and manufacture of high-performance Heating, Ventilation, and Air Conditioning (HVAC) systems. Established in 1914 and headquartered in Bryan, Ohio, USA, Bard has built over a century of excellence in providing durable and energy-efficient climate control solutions for commercial, industrial, and institutional applications.

MULTI-TEC Wall-Mount Air Conditioner

W18A*P - W72A*P & W18L*P - W36L*P

The MULTI-TEC Wall-Mount Air Conditioner utilize PLC technology to allow multiple units to operate connected to a single LC6000 controller. When installed with an optional 100% free cooling economizer, the unit will supply full-rated airflow in free cooling mode with the ability to exhaust unconditioned indoor air without the need for additional relief openings in the structure.

Features


·         PLC Control Module: Enables multiple units to operate via a single LC6000 controller

·         Copeland Scroll Compressors: Reliable and efficient performance

·         R-454B Green Refrigerant: Eco-friendly and compliant with environmental standards

·         Copper Tube / Aluminum Fin Coils: Durable and efficient heat exchange

·         Optional Free Cooling Economizer: Supplies full-rated airflow and exhausts indoor air without extra relief openings

·         Ventilation Options: Economizer, blank-off plate

·         Cabinet Colors: Beige, White, Buckeye Gray, Stainless Steel

·         Optional Equipment:

·         Electric or Hot Gas Reheat Dehumidification (W42A–W72A)

·         MERV11 or MERV13 Air Filters

·         LC6000 PLC Controller

·         Supply/Return Grille

Applications


·         Ideal for modular buildings, telecom shelters, equipment rooms, and industrial enclosures

·         Suitable for multi-unit installations requiring centralized control

·         Designed for exterior wall mounting, saving indoor space

·         Compatible with free cooling setups, enhancing energy efficiency in moderate climates

Specifications:


Model

Capacity (Tons)

Electrical Options

Supply/Return (HxW)

Spread (in)

Cabinet Dimensions (WxDxH in)

W18A

1.5

230/208-60-1

8x20 / 12x20

20.6

33.3 x 17.1 x 74.6

W18L

1.5

230/208-60-1

8x20 / 12x20

20.6

33.3 x 17.1 x 74.6

W24A

2

230/208-60-1, 230/208-60-3, 460-60-3, 240/220-50-1, 415/380-50-3

8x20 / 12x20

20.6

33.3 x 17.1 x 74.6

W24L

2

230/208-60-1, 230/208-60-3, 415/380-50-3

8x20 / 12x20

20.6

33.3 x 17.1 x 74.6

W30A

2.5

230/208-60-1, 230/208-60-3, 460-60-3, 240/220-50-1, 415/380-50-3

8x28 / 14x28

18

38.2 x 17.1 x 74.6

W30L

2.5

230/208-60-1, 230/208-60-3, 460-60-3, 415/380-50-3

8x28 / 14x28

18

38.2 x 17.1 x 74.6

W36A

3

230/208-60-1, 230/208-60-3, 460-60-3, 240/220-50-1, 220/200-50-3, 415/380-50-3

8x28 / 14x28

18

38.2 x 17.1 x 74.6

W42A

3.5

230/208-60-1, 230/208-60-3, 460-60-3, 415/380-50-3

10x30 / 16x30

30

42 x 25.5 x 84.8

W48A

4

230/208-60-1, 230/208-60-3, 460-60-3, 415/380-50-3

10x30 / 16x30

30

42 x 25.5 x 84.8

W60A

5

230/208-60-1, 230/208-60-3, 460-60-3, 220/200-50-3, 415/380-50-3

10x30 / 16x30

30

42 x 25.5 x 93

W72A

6

230/208-60-1, 230/208-60-3, 460-60-3, 415/380-50-3

10x30 / 16x30

30

42 x 25.5 x 93

Specification Details
AAA aaa
BBB bbb
Process Gas Analyzer
Image 1
Image 2
Image 3
Image 3
Image 3

Description


MODEL:OXYMON 

OXYMON Series Zirconia oxygen analyzer is an analyzer used to monitor and control the oxygen concentration of combustion gases, boilers and flue gas in industrial furnaces. It is widely used in industrial fields requiring a large amount of energy - such as steel mills, power plants, petroleum and petrochemical, ceramics, paper, food or textile industries, as well as various types of incinerators and medium/small boilers. In these areas, it can help save energy. It can also reduce the emissions of CO2, SOx and NOx by controlling complete combustion, and contribute to protecting the earth's environment, preventing global warming and air pollution.

The zirconia oxygen analyzer consists of a detection unit (oxygen probe) and a control unit (transmitter). Among them, the detection unit is installed on the flue, and the detector is composed of a dust proof device, zirconia tube, heating furnace, thermocouple, gas conduit, junction box and shell. The whole device adopts a fully enclosed structure to increase the sealing ability of the whole device and improve the service life. The control unit is the terminal for the user to operate the integrated functions, including the operation panel, the display interface, and the 4-20mA current output port. The oxygen analyzer with automatic calibration also includes a standard automatic order box.

Model: UT-IN Online Series  

UT-IN is a flameproof bypass type tunable laser gas analyzer for industrial on-line analysis and environmental on-line monitoring, especially suitable for harsh working condition such as high temperature, high humidity, high dust, and high board. The analyzer contains auto purge function with greatly reduces maintenance cost.

UT-IN laser gas analyzer consists of transmitter, received and gas cell. The transmitter drives the tunable diode to emit laser of certain wavelengths, which passes through the gas cell, then reaches the receiver. The receiver performs signal processing to obtain second harmonic signal, then calculates the concentration according to the relationship between the second harmonic signal and the gas concentration. 

Model: UT-IN-S-N-O-H-230

SO2-NO2-CO2 measurement:

• This analyzer uses UV absorption (for SO₂ and NO₂) and IR spectroscopy (for CO₂) in a compact, robust sensing head with LED light sources and no moving parts, requiring virtually zero maintenance.

Accuracy is ensured through automatic zero calibration using ambient air, with CO₂ scrubbed by a long-life disposable filter (2+ years replacement interval).

• Service needs are minimal: 36V DC power (@50 VA) and RS485 digital output via a single 4-way sealed connector.

NO/H2O Measurement:

• The NO/H₂O sensor uses the same in-situ probe design as the SO₂/NO₂/CO₂ sensor but employs a Quantum Cascade Laser (QCL) as the radiation source. The QCL provides a narrow, precise IR beam, allowing measurement of a single NO absorption line free from H₂O interference for highly accurate, noise-free readings. It simultaneously measures H₂O concentration using a nearby spectral line.

• Unlike traditional chemiluminescence (maintenance-heavy) or IR/UV methods (cross-sensitivity and short lamp life issues), the QCL offers long-term stability, no moving parts, and virtually zero maintenance, with a lifetime measured in decades.

• The analyzer measures NO from <10 ppm to several thousand ppm at temperatures up to 450 °C and can be adapted for other gases (e.g., NH₃) by selecting a suitable QCL wavelength, making it ideal for applications like SCR control in coal-fired power plants.

Model: UT-IN-S-N-O-H-230VAC

UT-IN series Flue Gas Analyzer is a highly integrated single-flange gas monitoring equipment, of which, core detection module adopts Tunable Diode Laser Absorption Spectroscopy (TDLAS), Differential Optical Absorption Spectroscopy (DOAS) gas absorption technology and Zirconia with independent intellectual property rights. The specially designed measuring cell effectively improves optical path length for gas absorption, which can measure trace gas accurately inside pipeline UT-IN series can be widely applied in online gas monitoring occasions including denitrification device, boiler flue and exhaust detection, etc. One equipment can realize online monitoring for multiple gas components, such as CO, CO2, SO2, NO, NO2, O2, H2O etc.

MODEL: OXYMON-ZPM

 It is widely used in N2 reflow furnace, N2 direct flow furnace, air separation device, gas puritymanagement, protective inert gas, ferrite sintering furnace and other environments to measureoxygen concentration

Model No: ZY-OXY-PM/PMD

The   ZY-OXY-PM   series   paramagnetic   gas   analyzer   is   based   on   the   characteristics   of   oxygen   with high paramagnetic. It can detect various concentrations of oxygen such as trace oxygen, constant oxygen and purity oxygen.  The magnetic mechanical principle has high analysis precision and long service life. It has non-explosion-proof and explosion-proof models and can be used in industrial hazard applications.

Model: UT-IN Series  

The laser gas analyzer can measure high-temperature (700°C), high-dust (50g/m3) flue gas,and can realize in-situ analysis at the work site; and the laser gas analyzer has a short response time, which is a true "real-time online" analysis instrument. It can be used to measure CO, CO2, O2, NH3, HCL, HF, CH4 and other gases. Provide real-time and accurate data for process monitoring, safety monitoring, and pollution monitoring.

Features


• Easy to Use and Low

Maintenance

• The Sensor adopts Ion coating technology ,which has strong anti-oxidation ability

• long service service life

• The Unique thermal diffusion reference design does not need special reference air pump/Instrument Air

• Extremely Low Oxygen potential long-terms drift

• High measurement accuracy and stable and reliable data

• The sensor adopts unique welding process ,which has high sealing performance and No leakage

• Suitable for harsh working conditions such as hightemperature, high humidity, high dust, high pressure,

• and for small pipes where a are not suitable for inside measurement occasions.

• Integrated structure design, high reliability and

• Stability

• “Single Line Spectrum”

• Technology, free from interface of background

• Gas.

• Innovative Hall button design, high sensitivity,

• Easy operation.

• Adopts imported TO encapsulate semiconductor laser, optical noises are restrained with antireflective coating end cap.

• Easy installation and operation

• Low maintenance

• INSITU CEMS suitable for Refineries, power plant & other industries.

• Measurement gas resolution 1 PPM and accuracy +/-2% of reading

• UV absorption spectroscopy based SO2 & NO2 measurement, Laser (QCL) based NO & H2O measurement and Infrared spectroscopy-based CO2 measurement

• Remote monitoring of system available.

• Simple Installation as per the photograph

• Light weight so easy to installation.

• Low maintenance cost

• No Shelter required

• Adopt single-flange design with high integration

• and easy installation

• Measurement gas resolution 1 PPM and accuracy +/-2% of fs

• Remote monitoring of system available.

• Simple Installation as per the photograph

• With high-temperature flowmeter, user can

• observe flow during equipment operation

• Low maintenance cost

• Sampling measurement is free from interference of pipeline deformation, high dust and other working condition change, with strong adaptability

• No Shelter required

• The imported new-type longevously zirconia detector is with high accuracy and a rapid response speed for features, etc.;

• N2 or O2 Display mode available;

• The auto-compensation system for temperature with high accuracy could eliminate the influence from the environment temperature;

• The accurate measurement of oxygen concentration among the range of ppm~% can be met through one-point calibration in the air;

• The size is small and easy to maintain;

• The auto-compensation system for temperature with high accuracy could eliminate

• the influence from the environment temperature.

• The upper and lower alarm limits can be set freely among the whole range

• The mechanical dumbbell type paramagnetic principle has high precision, short preheating time, quick response and good linearity,

• Direct measurement of the paramagnetic properties of oxygen with low gas interference.Compared to electrochemical sensor, it adopts non-consumable components, the normal lifespan can last over 1O years.Trace, constant, purity oxygen, multi-range is optional. LCD display, concentration curve, history data and other information display.

• RS485 signal output, relay output, compatible with various control systems. Standard 19-inch chassis design(non-explosion-proof}, can be equipped with sampling system for mast of working conditions.

• Thick carbon steel casing {explosion-proof type). explosion-proof grade up to ExdllCT6, can be used in explosive hazardous areas.

• Soft boot and watchdog functions, to keep a stable work without crash

• High Precision, Extremely Low Drift

• High selectivity, No Cross interference

• High temperature gas can be measured, up to 700 deg C

• It can measure complex gas mixture and their component changes

• No affected by dust

• Reponse time <1s

• Long maintenance period and low cost

• long service service life

• Suitable up to 50 g/m3 dust load

Specifications:


Technical ParameterSpecification
Model No.UT-IN Series
Measuring PrincipleTDLAS (Tunable Diode Laser Absorption Spectroscopy)
Measuring Gas Chamber Length200–1000 mm
Measuring Gas Chamber MOCSS316L / Hastelloy (Customizable)
Preheating Time< 15 minutes
Response Time (T90)< 30 seconds (depending on working conditions)
Accuracy±1% FS
Span Drift±1% FS
Repeatability±1% FS
Maintenance Intervals< 2 times/year, clean optical window (no consumables needed)
Calibration Intervals< 2 times/year
Operating TemperatureUp to 700°C
Protection ClassIP66
Area ClassificationSuitable for hazardous areas (Exd IIC T6)
Analog Signal Output4–20mA isolated current output (max load 500 ohms)
Analog Input4–20mA current (temperature and pressure compensation, optional)
Digital OutputRS485 / RS232
Relay Output3-wire output (24V, 1A)
Power Supply24VDC / 110–230VAC, 50/60Hz, <40W
Purge Gas2–8 bar Industrial N₂ or Purified Instrument Air
Ambient Temperature–20°C to +60°C
Transmitter & Receiver EnclosureCast aluminum shell
InstallationWall-mounted
Sample IN/OUT Connection6mm / 8mm (customizable as per requirements)

ParameterDescription
MeasurementSO₂, NO₂, CO₂, NO / H₂O
TechnologySO₂–NO₂–CO₂: UV Absorption Spectroscopy
NO / H₂O: Quantum Cascade Laser (QCL)
Range (SO₂–NO₂–CO₂ Measurement)SO₂: 0 to 500 / 1000 ppm
NO₂: 0 to 500 / 1000 ppm
CO₂: 0 to 10%
(Other measurement ranges customizable)
Range (NO–H₂O Measurement)NO: 0 to 500 / 1000 ppm
H₂O: 0–20%
(Other measurement ranges customizable)
Probe MOCSS 316
AccuracySO₂: ±2 ppm or ±2% of reading
NO₂: ±2 ppm or ±2% of reading
CO₂: ±0.1% CO₂
NO: ±1 ppm or ±2% of reading
H₂O: ±0.1% H₂O
ResolutionSO₂ / NO₂ / NO: 1 ppm
CO₂ / H₂O: 0.1%
Protection LevelIP65
Probe Length300 mm / 500 mm / 1000 mm (customizable per site requirements)
Response TimeT90 < 100 seconds
Analog OutputEach parameter 4–20 mA output
Digital InterfaceRS485 (Modbus)
Ambient Temperature–20°C to +55°C
Power Supply100–240 VDC, ±10% FS, 50/60 Hz
PurgingInstrument Air
Calibration FacilityUsing Calibration Standard Cylinder
Work Temperature (Flue Gas)0°C to 450°C
Weight< 30 kg



ParameterDescription
MeasurementSO₂, NO, NO₂, CO, CO₂, O₂ / H₂O
Measurement TechnologySO₂ / NO / NO₂: DOAS (Ultraviolet Differential Absorption Spectroscopy)
CO / CO₂: TDLAS (Tunable Diode Laser Absorption Spectroscopy)
O₂ / H₂O: Zirconia-based Sensor
Measurement RangeSO₂: 0 to 500 / 1000 / 2000 / 3000 / 5000 ppm
NO: 0 to 500 / 1000 / 2000 / 3000 / 5000 ppm
NO₂: 0 to 500 / 1000 / 2000 / 3000 / 5000 ppm
CO: 0 to 500 / 1000 / 2000 / 3000 / 5000 ppm
CO₂: 0 to 20 / 25%
O₂: 0 to 20 / 25%
H₂O: 0 to 40%
(Other measurement ranges customizable)
Probe MOCSS316 / SS316L
Probe Length500 mm / 1000 mm / 1500 mm / 2000 mm (customizable as per site requirements)
Accuracy± 2% FS
Repeatability± 1% FS (under standard conditions)
ResolutionSO₂ / NO / NO₂ / CO: 1 ppm
CO₂ / H₂O: 0.1%
Zero Drift± 2% FS / 30 days
Span Drift± 2% FS / 30 days
Protection LevelIP65
Response TimeT90 < 90 seconds
Analog OutputEach parameter 4–20 mA output
Digital InterfaceRS485 (Modbus)
Ambient Temperature–20 °C to +60 °C
Ambient Humidity≤ 90%, non-condensing
Power Supply110 / 240 VDC, ±10% FS, 50/60 Hz
Instrument Air Supply3–5 bar, oil-free, water-free and dust-free air
Calibration FacilityUsing calibration standard cylinder
Work Temperature (Flue Gas)0 to 350 °C
Weight< 45 kg

ParameterDescription
Model No.OXYMON-ZPM
Measurement DisplayO₂ or N₂
Measuring PrincipleZirconia
Measuring Range0–10 / 100 / 1000 PPM / 21% (User Configurable)
Accuracy± 1.5% FS
Repeatability± 1.0% FS
Operating Temperature0°C to 60°C
Ambient Temperature–10°C to 50°C
Sample ModeSample Gas In
Sample Gas Flow300–500 ml/min
Sample Gas Pressure95 kPa – 105 kPa
Sample In & Out Port Size6 mm
Response TimeT90 < 30 seconds
Background GasNitrogen and Oxygen mixed gas
Power Supply85–240 VAC, 50/60 Hz, 250 VA
Analogue Output4–20 mA Isolated, 500 Ω max
Size (HxWxD)80 × 160 × 142 mm
Install Cut Out (HxW)76 × 151 mm
Relay Output1 No. potential-free contact
Service Life> 22,000 hours (under normal use)
Install ModeFrame mount or retaining clamp carried by the Oxygen sensor

ParameterDescription
ModelZY-OXY-PM: Non–Explosion Proof
ZY-OXY-PMD: Explosion Proof
Measuring RangeO₂: 0–5% / 15% / 30% / 100% VOL
PrincipleCustomized Paramagnetic
Accuracy± 0.1% VOL
Resolution0.01% / 0.1% VOL (depending on range)
Repeatability± 0.5%
Zero Drift± 0.5% FS / 7 days
Span Drift± 0.5% FS / 7 days
Response Time (T90)≤ 5 seconds
Image 3

Description


The  SE - DEW - 100  Dewpoint Transmitter makes monitoring  dewpoints  as  easy  as  measuring temperature  or  pressure,  and  can  be  instantly incorporated  into  air  or  gas  measurement  and control  systems.  We  highly  automated manufacturing,  calibration  and  test  processes make the  SE - DEW - 100  not only a very rugged and reliable instrument but also very competitive in price. By taking advantage of sensor program, users can be assured that their process moisture measurement  facility  is  never  interrupted.  It  is very easy to install and maintain and comes with a full world-wide backup and service program.

Features


• 4-20 mA 2-wire loop powered connection

• Dewpoint OR parts per million (moisture content) in volume (PPM(V) measurements

• Accuracy ±2°Cdp

• Repeatability ±0.5°Cdp

• Dewpoint values traceable to international standards

• Excellent detector element protection

• Rugged stainless steel construction

• Fully interchangeable

Applications


  • Compressed Air
  • CNG Stations
  • Moisture in Liquids
  • Medical Gas
  • Trace Moisture

Specifications:


- Measurement Range: -100 to +20°C dew point

- Accuracy: ±2°C dew point

- Response Time: 1 minute to T95 (dry to wet)

- Repeatability: 0.5°C dew point

- Calibration: Traceable 7-point calibration certificate

- Output Signal: 4–20 mA (2-wire)

- Supply Voltage: 8–36 V DC

- Current Consumption: 20 mA max

- Operating Temperature: -40 to +60°C

- Operating Humidity: 0–100% RH

- Flow Rate:

 0.2 to 5 Nl/min (mounted in standard sampling block)

 0 to 10 m/s (direct insertion)

- Temperature Coefficient: Temperature compensated across operating range

- Ingress Protection: IP65

- Housing Material: Stainless steel

- Dimensions: 114 mm length × 30 mm diameter

- Weight: 170 g

- Filter: 20 µm sintered guard

Ranges:

​Range by sensor type:

XTR-100 -148° to 68°F (-100° to 20°C)

XTR-65 -85° to 68°F (-65° to 20°C)

Pressure Operating Range:

Standard 500 psi (34 Bar)

Optional 5,000 psi (340 Bar)

​Readouts: Dewpoint in °F and °C, ppmv, H2O/m3, lbs H2O/mmscf

​Sensor Type: High capacitance Al2O3 (HTF)

​Accuracy: ​± 5.5°F (± 3°C)

Repeatability: ± 0.9°F (± 0.5°C)

Capacitance: 15 nF to 200 nF

Temperature:

Sample: 22° to 122°F (-30° to 50°C)

Electronics: 14° to 122°F (-10° to 50°C)

​Response Time:

​For a step change from -40° to -76°F (-40° to -60°C)

63% in 90 seconds

90% in 450 seconds

​Mechanical Connections:

​14 mm x 1.25 mm threads and 3/4″ – 16 threads

Flow cell with 1/4″ tube fitting (option)

​Electrical Connections: Female BNC connector

​Intrinsically Safe Option: Class 1 & 2, Division 1, Groups A, B, C, D, E, F & G

(when used with optional safety barriers)

​Display/Indicator: ​Back-lit LCD, 3.5 digits

​Controls: 4 push buttons

​Power: 100-240 VAC, 50/60 Hz

​Output: ​0/4-20 mA, RS-232

​Sensor Cable: Coaxial cable (75Ω with capacitance of 50 pF/M)

Maximum cable length = 3,000 ft​ (914.4 m)

Flow Meters
Image 1
Image 2

Description


ECO-FLASH, flash vessels are used for separation of flash steam from high pressure condensate thereby generating useful low pressure steam totally free of cost. ECO-FLASH is supplied with all standard accessories like safety valve, pressure gauge, Valve, double window sight glass, steam trap and strainer.
A flow meter is a device used to measure the volume or mass of a gas or liquid.  Flow meters are referred to by many names, such as flow gauge, flow indicator, liquid meter, flow rate sensor, etc. depending on the particular industry. However, they all measure flow.  Improving the precision, accuracy, and resolution of fluid measurement are the greatest benefits of the best flow meters.

Features


• Wide range of nominal diameter Size ½” to 28” (15 mm to 700 mm) with IP68 protection

• Easy maintenance due to no moving parts

• Uninfluenced by temperature, pressure, viscosity, and density

• Used for wide application, can measure conductive fluid, without reference to fibre, solid or suspending material contained in liquid

• High turndown ratio up to 1:100

• It features high intelligence, with back light LCD display, menu setting control, three grades password protection, two-way measuring, slight signal removal, auto flow compensation, and other function.

• Features high intelligence, which ensure empty pipe detection, self-detection, self-diagnostic functions, and safety alarms for upper and lower limit

• Features SMART excitation, which ensures zero-point stability, high reliability, and low power consumption

• Lining and electrode available in various materials which can measure nearly all conductive fluids

• It has multiple signal output, pulse, Modbus RS485 or HART® or 4 to 20 mA

• It has lower measuring limit, better stability, and accuracy

• It has a unique dual sensor design

• Special signal processing method provides better antivibration

• More reliable performance

• Requires less maintenance

• It can calculate density and mass flow rate without mass flow computer

• It has self-diagnostic function

• Optional multivariable version is available, has in-built RTD and pressure sensor that can measure and display flow rate, velocity, temperature, pressure, mass flowrate, and density

• Self-diagnostic function is available

• Measurement of mass flow, density, temperature and volume flow

• Suitable for aggressive and contaminated media

• Measurement and display of percent water-cut for oil/water mixtures

• High rotation frequency and well-balanced measuring tubes

• Higher Sampling and Digital Filtering

• No moving parts

• Can be used in extreme harsh conditions

• High accuracy for measuring mass flow, density, temperature and volume flow

Benefits


• Wide range of nominal diameter Size ½” to 28” (15 mm to 700 mm) with IP68 protection

• Easy maintenance due to no moving parts

• Uninfluenced by temperature, pressure, viscosity, and density

• Used for wide application, can measure conductive fluid, without reference to fibre, solid or suspending material contained in liquid

• High turndown ratio up to 1:100

• It features high intelligence, with back light LCD display, menu setting control, three grades password protection, two-way measuring, slight signal removal, auto flow compensation, and other function.

• Features high intelligence, which ensure empty pipe detection, self-detection, self-diagnostic functions, and safety alarms for upper and lower limit

• Features SMART excitation, which ensures zero-point stability, high reliability, and low power consumption

• Lining and electrode available in various materials which can measure nearly all conductive fluids

• It has multiple signal output, pulse, Modbus RS485 or HART® or 4 to 20 mA

• It has lower measuring limit, better stability, and accuracy

• It has a unique dual sensor design

• Special signal processing method provides better antivibration

• More reliable performance

• Requires less maintenance

• It can calculate density and mass flow rate without mass flow computer

• It has self-diagnostic function

• Optional multivariable version is available, has in-built RTD and pressure sensor that can measure and display flow rate, velocity, temperature, pressure, mass flowrate, and density

• Self-diagnostic function is availablet

• Measurement of mass flow, density, temperature and volume flow

• Suitable for aggressive and contaminated media

• Measurement and display of percent water-cut for oil/water mixtures

• High rotation frequency and well-balanced measuring tubes

• Higher Sampling and Digital Filtering

• No moving parts

• Can be used in extreme harsh conditions

• High accuracy for measuring mass flow, density, temperature and volume flow

Applications


• It can measure highly corrosive medium such as concentrated acid and concentrated alkaline using PTFE lining material.

• By using Hastelloy C electrode we can measure seawater and brine application Trace humidity in oxygen purity.

• It is used to measure gas, steam, and liquid.

• Cleaning and Sterilization (SIP and CIP) process in food, beverage, and pharmaceutical industries

• It is used in various industries like petrochemical, water and waste water, food and beverages

• Used to measure steady uniform flow of common viscous fluid, non-Newtonian fluid, slurry containing some solid components, and liquids containing some trace of gases.

• Suitable for the bulk measurement of products like syrup, molasses, and raw chemicals.

Specifications:


Service: Compatible conductive liquids

Measuring Range: flow range please refer the catalog

Lining Materials: PTFE and Synthetic rubber

Electrode Material: Stainless Steel, Hastealloy C

Accuracy: ±0.5%

Repeatability: 0.15%

Ambient Temperature Limits:

sensor (Remote Mount): -4 °F to 158 °F (-20 °C to 70 °C)

Converter: -4 °F to 122 °F (-20 °C to 50 °C)

Integral Type: 14 °F to 122 °F (-10 °C to 50 °C)

Ambient Magnetic Field: ≤ 400 A/m

Pressure Limit: ≤ 150 PSI

Mounting Orientation: Horizontal or vertical

Process Connection: #150 ANSI or AWWA flanges

Output Signal: Pulse and 4 to 20 mA or Modbus RS485 or 4 to 20 mA with HART

Power Requirements: 18 VDC to 28 VDC or 85 VAC to 220 VAC

Conductivity: ≥5 μs/cM

Enclosure Rating: IP68

Agency Approvals: CE

Service: Liquids, Gas, Steam

Max. Flow Range :

Gas: 197 ft/s

Liquid: 23 ft/s

Steam: 230 ft/s

Accuracy: ±1% of reading

Repeatability: 0.3% of reading

Ambient Temperature Limits: -40 °F to 662 °F (For standard vortex only)

Pressure Limit: As per flange rating

Mounting Orientation: Horizontal

Process Connection: Wafer or ANSI flange

Output: 4 mA to 20 mA or Pulse or 4 mA to 20 mA with HART or Modbus RS485

Power Requirements: 24 VAC or 13.5 VDC to 42 VDC

Enclosure Rating: NEMA 4x (IP67)Agency Approvals: CE

Service: Liquids and Gas

Size: 

U shaped: 1½” to 8″

Microbend: ½” to 8″

Triangle: ½” to 1″

Measuring Ranges: For mass flow rates please refer the catalog

Accuracy: 0.1% or 0.2% or 0.5%

Density Measuring Range: 2 to 30 lb/gal (0.2 to 3 g/cm3)

Density Basic Error: ±0.02 lb/gal (±0.002 g/cm3)

Density Repeatability: ±0.01 lb/gal (±0.001 g/cm3)

Repeatability:

For 0.1% accuracy : ±0.05%

For 0.2% accuracy: ±0.1%

For 0.5% accuracy: ±0.25%

Temperature Limits:

Direct Mount: -58 °F to 257 °F (-50 °C to 125 °C)

Remote Mount:  -58 °F to 392 °F (-50 °C to 200 °C)

Power Requirements: 18 VDC to 28 VDC or 85 VAC to 220 VAC

Output signal: 4 -20 mA or Pulse, Optional: HART or Modbus RS485

Description


The Quench Water Sampler is used to take water samples from high-temperature and high-pressure lines for pH measurement. It cools the hot water sample to a safe temperature before it reaches the pH analyzer. This helps to protect the sensor and ensures accurate and reliable pH readings. The system is made of stainless steel for long life and safe operation.

Sampling System for Gas Detection Systems
Gas Detection Sampling System is designed to monitor Gas atmospheres. SEPL offers   customized sampling system based on different conditions. Standard sampling system consists of Isolation valves, blow down valves, rotameter, Air filters and the gas Detection system.

The Sample is passed through the sample system wherein we control the temperature, pressure and flow. The filtered and conditioned sample Gas is then passed across one or two different Detectors. This system is fault tolerant removing the need for expensive downtime and maintenance.

All transmitters have a 4-20 mA signal for direct connection to the site DCS, PLC or site control system. If needed we can provide local Alarms along with 4-20 mA output with a wide range of dry contacts, making the system very sophisticated and user friendly.

The Sea Water Sampling System is designed to safely collect representative seawater samples for chemical, biological, or physical analysis. It ensures accurate sampling from different depths or locations while preventing contamination. The system can handle high salinity, varying temperatures, and offshore conditions, making it ideal for marine research, environmental monitoring, and industrial applications.

Features


- Designed for high-pressure and high-temperature applications.

- Built-in cooler to reduce sample temperature.

- Provides accurate and stable pH readings.

- Made from corrosion-resistant stainless steel (SS316).

- Compact and easy to install.

- Low maintenance design.

- Suitable for online or offline pH measurement.

- Continuous and reliable gas sampling from remote or inaccessible locations

- Compact, modular, and easy-to-install design

- Compatible with various gas analyzers and sensors

- Corrosion-resistant stainless steel or aluminum construction

- Integrated sample conditioning (filters, coolers, flow control)

- Low maintenance and easy access for servicing

- High accuracy and repeatability of gas measurements

- Optional alarm and safety interlocks

• Suitable for sampling seawater at different depths and locations

• Corrosion-resistant construction (SS316, titanium, or specialized alloys)

• Compact, modular, and easy to install on ships, platforms, or coastal stations

• Optional automated or manual operation

• Sample conditioning (filters, flow control) to protect analyzers

• Compatible with online analyzers or offline laboratory testing

• Low maintenance and long service life

Benefits


- Enables safe monitoring of hazardous areas

- Protects gas analyzers from moisture, dust, and temperature effects

- Ensures accurate and stable gas readings

- Reduces maintenance and downtime

- Customizable per process or analyzer requirements

- Improves plant safety and compliance with emission standards

• Ensures accurate and representative samples for analysis

• Protects sensors and analyzers from salt and debris

• Enables continuous or periodic monitoring of seawater quality

• Reduces human error and manual handling risks

• Enhances environmental compliance and research quality

• Robust design suitable for harsh marine environments

Applications


- Power plants (boiler and condensate systems)

- Refineries and petrochemical plants

- Chemical and fertilizer industries

- Water treatment plants

- Steam and water analysis systems (SWAS)

- Power plants (flue gas and emission monitoring)

- Refineries and petrochemical plants

- Steel and cement industries

- Fertilizer and chemical plants

- Waste incineration and environmental monitoring

- Gas turbine and boiler exhaust systems

Specifications:


- Sampling Flow Rate: 0.5 – 5 LPM (adjustable)

- Sample Pressure: Up to 10 kg/cm²

- Sample Temperature: Up to 150°C

- Sample Line Length: Up to 50 meters (depending on design)

- Material of Construction: SS304 / SS316 / Aluminum

- Filtration: 5-micron replaceable filter

- Power Supply: 230 VAC / 24 VDC (as required)

- Mounting Type: Wall Mounted / Skid Mounted

- Cooling Medium: Air or Water (if required)

- Analyzer Interface: Suitable for online gas analyzers

- Operating Temperature: 0°C – 55°C

- Enclosure Rating: IP54 / IP65

• PVDF/CPVC, Monel tube

• Sample coolers with PVDF, CPVC, PTFE material and wetted parts

• Filters with wetted parts of PVDF/CPVC/Monel

• Flow meters

• Mounting plate with 5 mm thick CPVC sheet

• Suitable for Desalination plants, Sea water quality monitoring, Effluent monitoring

• Oil in water sampling systems

• Salinity Analyzer

• Turbidity Analyzer

• pH and conductivity sampling systems

Sr. No.ParameterSpecification
1Sample PressureUp to 100 kg/cm²
2Sample Temperature (Inlet)Up to 300°C
3Sample Temperature (Outlet)25°C to 40°C (after cooling)
4Cooling MediumCooling Water
5Flow Range100 – 500 ml/min (adjustable)
6Construction MaterialSS316 / SS316L
7Connection Type¼” or ½” NPT / Compression Fittings
8Mounting TypeWall Mounted / Panel Mounted
9Application MediumQuench Water / Condensate / Boiler Feedwater
10Measurement ParameterpH (via Analyzer / Electrode)
11Design TypeCompact and Modular
12Cooling TypeCounter Flow Cooling Arrangement
13MaintenanceEasy to Service and Clean
14Operating EnvironmentIndoor / Outdoor (as per system design)
Degassed Cation Conductivity
Image 1

Description


A new design for conductivity measurement for power cycle chemistry monitoring. By providing conductivity measurement in compliance with ASTM D4519, this system provides assurance of water purity to maximize power production and minimize corrosion. Unambiguous measurement of trace levels of corrosion causing contaminants is enabled with effective operator supervision. A must product for startup and supercritical Boilers

Features


• All conductivity measurements

• No external cooling water required

• Stainless steel construction

• Multi-parameter transmitter with single-screen display of all measurements

• Very High Accuracy

• Auto Ranging

• Integrated flow sensor with automatic heater shut-off if flow stops

• Precise detection of corrosive contaminants

• Inferred pH and CO2

• Trend graphs for all measurements

• Universal PCB

• Digital Sensors

• Emergency stop button

• Low flow cutoff

Benefits


• Faster Plant startups and simpler turbine warranty compliance

• Easy displaying and monitoring of sample conditions

• Protects the system from thermal damage and maintenance

• Understand plant characteristics better and plan maintenance, avoiding plant shutdowns

• Colour indicating Resin for depletion

• Alerts for changeover of Cation Column

Applications


• Feed Water and Steam Monitoring

• Power Plant Steam Quality Monitoring

• Power Plant Condensate Monitoring

Specifications:


Measuring principle: Degassing by heating

Measurements: Continuous Flow through type for Continuous measurement of Specific Conductivity, Cation Conductivity, Degassed Cation Conductivity values

Measuring Range:

a. Specific conductivity-0-100µS/cm

b.Cation conductivity- 0-10µS/cm

c. Degas conductivity-0- 1µS/cm

d.Freely programmable

No of stream: Single

Accuracy: < +/-1 % of fs

Response Time: T90 <=5 sec

Temperature Compensation: Automatic

Analog Output: Separate 4-20mA outputs for transmitting specific conductivity , Cation conductivity and Degassed Cation conductivity

Display: Larger Touch screen ,5.7” resolution 320×240 pixels,QVGA256 colors

Power Supply: 220-240 VAC,50 Hz

Ambient Temperature: 5 to 45 deg C

Relative Humidity: 10 to 90% non-condensing

Sample Flow Rate: 100-250 mL/min

Sample Temperature & Pressure: 10 to 45 degC &:0.2 to 4 Ksc

Ratings / Approvals: IP 65

Panel Body materials: SS316

Wetted part materials: SS316

Mounting: Plate mounting as per provided site conditions.

Sampling system:

SS 316 wall mounted sampling system

• Needle valve-1/4” SS316

• Pressure regulator

• Rota meter with regulator

• Flow through chamber

• Heater

• Cooling system

• SS sample tubing’s and fittings.

Chiller
Image 1

Description


SEL’s chiller is designed with sufficient refrigeration capacity to ensure that sample stream temperature is up to 25oC ±1oC. It is fabricated with complete stainless-steel construction. Chiller is of direct expansion type with refrigerant tubes inside a shell, completely insulated and to be constructed in accordance with the ASME code. Refrigerant circuit consists of components such as thermostatic expansion valve, liquid line solenoid valve, sight glasses, filter-dryer, refrigerant shut-off and charging valves.

All Systems are designed in compliance with ASME PTC-19.11, USA, GDCD, UK, EPRI, VGB Standard S006-2012

Features


• Compact skid mounted chiller system, ready to install.

• Chillers are fully automatic with tried & tested controls.

• Quick chilling is ensured with plate type or shell and tube evaporators.

• Chillers use energy saving with cycling fans and high efficiency fin     tube air-cooled condensers with liberal sized fans.

• Chillers offer guaranteed cooling capacity at rated parameters.

• Specific design to meet customer requirement for various temperatures available in addition to standard models.

Applications


• In sample handling systems, chillers are used to achieve outlet temperature of sample at 25oC. Chiller package is one of the important & valuable element of SWAS Unit.

Description


The shelter is constructed as a fully insulated sandwich construction with CRCA / SS-304 / SS-316L, making it suitable for ambient conditions. We have customized solutions for the customer. It can be provided with HVAC system. The complete shelter is designed, fabricated and tested in-house as an integrated system. The design of the analyzer shelter consider many factors like Local ambient conditions, hazardous area classification, sample type, analyzer type together with client specifications, will all influence the final design and content of the shelter.