Online Extractive Flue Gas Analyzer
Image 1

Description


Model: UT-Ex-S-N-O-H-230VAC

The NDIR gas analyzer can be used to continuously measure CO and CO2 、CH4 、SO2, NOand other gas concentration, can simultaneously measure one or more of the gas components. This Infrared gas analyzer is a multi-channel, multi-component analysis instrument. The instrument adopts the world's most advanced infrared gas detection technology. With excellent stability, selectivity and high sensitivity, it can be widely usedin boiler, power plant flue gas, chemical process, petrochemical industry, metallurgicalindustry and other fields, and can also be used for laboratory analysis

Features


• The sensor unit can bemeasured continuously SO2,NO、CO,CO2、CH4, O2、C2H4C3H8, TCH and other gasconcentration

• Multiple components can beanalyzed simultaneously

• Multi-channel 4-20 mA analogoutput and relay contactoutput.

• Automatic calibration, faultself-diagnosis, and digitalcommunication functions

• High accuracy and good stability

• ppm and mg/m3 are optional

• Very short preheating time- -5 minutes

• The instrument operation is simple, fast setting and convenient operation

• Use automatic air instrument for calibration zero (<5% CO2, zero must be calibratedwith N2)

• The interval of instrument range calibration every 3 months according to theenvironmental conditions

Specifications:


Response time from Analyser Sensor Inlet port (T90)

<40~50 seconds

 

reheating time

 

30min

 

Communication interface

 

RS232/RS485

Analogue output

Each parameter 4-20mA

 

Alarm output

 

Passive contact signals

 

Operating temperature

0 to 50°C

 

Atmospheric pressure

86~108kPa

 

Relative humidity

5 to 85 %

 

Operating

power 110VAC or 230VAC ,±10% ,50Hz 2A

 

Instrument weight

approx. 15~20 kg


SO2/NO



ZIRCONIA OXYGEN ANALYZER
Image 1

Description


MODEL:OXYMON 

OXYMON Series Zirconia oxygen analyzer is an analyzer used to monitor and control the oxygen concentration of combustion gases, boilers and flue gas in industrial furnaces. It is widely used in industrial fields requiring a large amount of energy - such as steel mills, power plants, petroleum and petrochemical, ceramics, paper, food or textile industries, as well as various types of incinerators and medium/small boilers. In these areas, it can help save energy. It can also reduce the emissions of CO2, SOx and NOx by controlling complete combustion, and contribute to protecting the earth's environment, preventing global warming and air pollution.
The zirconia oxygen analyzer consists of a detection unit (oxygen probe) and a control unit (transmitter). Among them, the detection unit is installed on the flue, and the detector is composed of a dust proof device, zirconia tube, heating furnace, thermocouple, gas conduit, junction box and shell. The whole device adopts a fully enclosed structure to increase the sealing ability of the whole device and improve the service life. The control unit is the terminal for the user to operate the integrated functions, including the operation panel, the display interface, and the 4-20mA current output port. The oxygen analyzer with automatic calibration also includes a standard automatic order box.


Features


• Easy to Use and Low

Maintenance

• The Sensor adopts Ion coating technology ,which has strong anti-oxidation ability

• long service service life

• The Unique thermal diffusion reference design does not need special reference air pump/Instrument Air

• Extremely Low Oxygen potential long-terms drift

• High measurement accuracy and stable and reliable data

• The sensor adopts unique welding process ,which has high sealing performance and No leakage

Specifications:


Technical Parameter

Model No.

OXYMON

Digital Output

RS485 Modbus (Optional)

Measuring Principle

Zirconia Oxide

Relay output

1 Nos Potential free

Measuringrange                               

0-25%(User Configurable)   

Display and Installation mode

LCD , Wall mount External display

Accuracy                           

± 0.5 % FS

Ambient Temperature

-20 ~ 65° C

Repeatability

± 0.5 % FS

O2 Probe Material

SS316L or SS304

Low detection Limit

0.01%

O2 Probe Length

200mm to 3000mm (Customizable)

Operating Temperature

0-700° C (Customizable up to 1400° C)

O2 Probe Flange connection

DN50 (2”)/DN100 (4”) (Customizable)

Operation Pressure

-10 KPa to +5kpa

O2 Probe Filter material

Ceramics (As per dust load)

Flue gas flow rate

0~50 m/s

O2  Probe mounting Angle

Horizontal, Vertical down

Response Time

T90 < 5 Sec

Detection type

Insert directly

IP Grade

IP 65/IP66

Process connection

DN50/DN100 Flange (Size Customized as per requirements)

Power Supply                        

110VAC/230 VAC,50/60Hz , 250VA

Calibration

Manual , Auto (Optional)

Analogue  Output

4-20 ma Isolated ,500Ω max

Standard Accessories

Probe protection tube , Mounting Spool piece , Interconnection cable and Manual Cal/Auto Cal. kit

TDLAS based Online Analyzer
Image 1

Description


Model: UT-IN Online Series  

UT-IN is a flameproof bypass type tunable laser gas analyzer for industrial on-line analysis and environmental on-line monitoring, especially suitable for harsh working condition such as high temperature, high humidity, high dust, and high board. The analyzer contains auto purge function with greatly reduces maintenance cost.

UT-IN laser gas analyzer consists of transmitter, received and gas cell. The transmitter drives the tunable diode to emit laser of certain wavelengths, which passes through the gas cell, then reaches the receiver. The receiver performs signal processing to obtain second harmonic signal, then calculates the concentration according to the relationship between the second harmonic signal and the gas concentration. 

Features


• Suitable for harsh working conditions such as hightemperature, high humidity, high dust, high pressure,

• and for small pipes where a are not suitable for inside measurement occasions.

• Integrated structure design, high reliability and

• Stability

• “Single Line Spectrum”

• Technology, free from interface of background

• Gas.

• Innovative Hall button design, high sensitivity,

• Easy operation.

• Adopts imported TO encapsulate semiconductor laser, optical noises are restrained with antireflective coating end cap.

• Easy installation and operation

• Low maintenance

Specifications:


Technical Parameter

Model No.

UT-IN Series

Measuring Principle

TDLAS (Tunable diode laser absorption spectroscopy)

Measuring gas chamber length

200~1000mm

Measuring gas chamber MOC

SS316L / Hastelloy (Can be customized)

Preheating time

<15 min

Response time (T90)

<30 Sec (related to the working condition)

Accuracy                           

± 1 % FS

Span drift

± 1 % FS

Repeatability

± 1 % FS

Maintenance Intervals

<2 times /Year, Clean optical window (No consumables need)

Calibration Intervals

<2 times/year

Operating Temperature                          

Up to 700° C

Protection class

IP66

Area classification

Suitable for Hazardous area (Exd IIC T6)

Analog signal

4-20mA Isolated Current output (max load 500 ohms)

Analog input                              

4-20mA Current (Temp., Pressure compensation) Optimal

Digital Output

RS485/RS232

Relay Output

3-wire output (24V ,1A)

Power Supply                        

24VDC / 110VAC~230 VAC,50/60Hz, <40W

Purge Gas                   

2 to 8 bars Industrial N2, Purification Instrument Air

Ambient Temperature

-20 ~ 60° C

Transmitter & Receiver Enclosure Material

Cast aluminum shell

Installation

Wall mount

Sample IN /OUT connection

6mm/8mm (Size Customized as per requirements)

ONLINE IN-SITU Type Flue Gas Analyzer
Image 1
Image 2

Description


Model: UT-IN-S-N-O-H-230

SO2-NO2-CO2 measurement:

• This analyzer uses UV absorption (for SO₂ and NO₂) and IR spectroscopy (for CO₂) in a compact, robust sensing head with LED light sources and no moving parts, requiring virtually zero maintenance.

Accuracy is ensured through automatic zero calibration using ambient air, with CO₂ scrubbed by a long-life disposable filter (2+ years replacement interval).

• Service needs are minimal: 36V DC power (@50 VA) and RS485 digital output via a single 4-way sealed connector.

NO/H2O Measurement:

• The NO/H₂O sensor uses the same in-situ probe design as the SO₂/NO₂/CO₂ sensor but employs a Quantum Cascade Laser (QCL) as the radiation source. The QCL provides a narrow, precise IR beam, allowing measurement of a single NO absorption line free from H₂O interference for highly accurate, noise-free readings. It simultaneously measures H₂O concentration using a nearby spectral line.

• Unlike traditional chemiluminescence (maintenance-heavy) or IR/UV methods (cross-sensitivity and short lamp life issues), the QCL offers long-term stability, no moving parts, and virtually zero maintenance, with a lifetime measured in decades.

• The analyzer measures NO from <10 ppm to several thousand ppm at temperatures up to 450 °C and can be adapted for other gases (e.g., NH₃) by selecting a suitable QCL wavelength, making it ideal for applications like SCR control in coal-fired power plants.

Features


• INSITU CEMS suitable for Refineries, power plant & other industries.

• Measurement gas resolution 1 PPM and accuracy +/-2% of reading

• UV absorption spectroscopy based SO2 & NO2 measurement, Laser (QCL) based NO & H2O measurement and Infrared spectroscopy-based CO2 measurement

• Remote monitoring of system available.

• Simple Installation as per the photograph

• Light weight so easy to installation.

• Low maintenance cost

• No Shelter required

Specifications:


Parameter

   Description

Measurement

SO2, NO2, CO2, NO/H2O

Technology

SO2-NO2-CO2: UV absorption spectroscopy

NO/H2O: Quantum Cascade Laser (QCL)

Range (SO2-NO2-CO2 measurement)

SO2       :0 to 500/1000 ppm

NO2:      0 to 500/1000 ppm

CO2:      0 to 10%

(Other measurement range can be customized)

Range (NO-H2O measurement)

NO:        0 to 500/1000 ppm

H2O:      0-20%

(Other measurement range can be customized)

Probe MOC

SS 316

Accuracy

SO2:     2ppm or 2% of reading

NO2:     2ppm or 2% of reading

CO2:     0.1% CO2

NO:        1ppm or 2% of reading

H2O:      0.1% H2O

Resolution

SO2/NO2/NO: 1 ppm

CO2/ H2O:   0.1%

Protection level

IP65

Probe length

300mm/500mm/1000mm

(Customized the length as per site requirements)

Response time

T90 <100 sec

Analog Output

Each parameter 4-20mA output

Digital Interface

RS485 Modbus

Ambient temperature

-20 to 55 °C

Power supply

100~240VDC, ±10% FS,50/60Hz

Purging

Instrument Air

Calibration facility

Using Calibration Standard cylinder

Work temperature (Flue gas temperature)

0 to 450 °C

Weights

<30 kg

ONLINE IN-SITU Type Flue Gas Analyzer
Image 1

Description


Model: UT-IN-S-N-O-H-230VAC

UT-IN series Flue Gas Analyzer is a highly integrated single-flange gas monitoring equipment, of which, core detection module adopts Tunable Diode Laser Absorption Spectroscopy (TDLAS), Differential Optical Absorption Spectroscopy (DOAS) gas absorption technology and Zirconia with independent intellectual property rights. The specially designed measuring cell effectively improves optical path length for gas absorption, which can measure trace gas accurately inside pipeline UT-IN series can be widely applied in online gas monitoring occasions including denitrification device, boiler flue and exhaust detection, etc. One equipment can realize online monitoring for multiple gas components, such as CO, CO2, SO2, NO, NO2, O2, H2O etc.

Features


• Adopt single-flange design with high integration

• and easy installation

• Measurement gas resolution 1 PPM and accuracy +/-2% of fs

• Remote monitoring of system available.

• Simple Installation as per the photograph

• With high-temperature flowmeter, user can

• observe flow during equipment operation

• Low maintenance cost

• Sampling measurement is free from interference of pipeline deformation, high dust and other working condition change, with strong adaptability

• No Shelter required

Specifications:


Parameter

Description

Measurement

SO2, NO, NO2, CO, CO2, O2/H2O

Measurement Technology

SO2/NO/NO2: DOAS (Ultraviolet Differential Absorption Spectroscopy)

CO/CO2: TDLAS (Tunable Diode Laser Absorption Spectroscopy)

O2/H2O: Zirconia based Sensor

Measurement Range

SO2:      0 to 500/1000/2000/3000/5000 ppm

NO:        0 to 500/1000/2000/3000/5000 ppm

NO2:      0 to 500/1000/2000/3000/5000 ppm

CO:        0 to 500/1000/2000/3000/5000 ppm

CO2:      0 to 20/25%

O2:         0 to 20/25%

H2O:      0 to 40%

(Other measurement range can be customized)

Probe MOC

SS316/SS316L

Probe length

500mm/1000mm/1500mm/2000mm

(Customized the length as per site requirements)

Accuracy

± 2% FS

Repeatability

± 1% FS (Under Standard condition)

Resolution

SO2/NO/NO2/CO:  1 ppm

CO2/ H2O:        0.1%

Zero drift

± 2% FS /30 Days

Span drift

± 2% FS /30 Days

Protection level

IP65

Response time

T90 < 90 sec

Analog Output

Each parameter 4-20mA output

Digital Interface

RS485 Modbus

Ambient temperature

-20 to 60°C

Ambient temperature

≤90%, Non-Condensing

Power supply

110 / 240VDC, ±10% FS,50/60Hz

Instrument Air Supply

3-5 bar, Oil-free, water-free and dust-free Air

Calibration facility

Using Calibration Standard cylinder

Work temperature (Flue gas temperature)

0 to 350 °C

Weights

<45 kg

ONLINE OXYGEN ANALYZER
Image 1

Description


MODEL: OXYMON-ZPM

 It is widely used in N2 reflow furnace, N2 direct flow furnace, air separation device, gas puritymanagement, protective inert gas, ferrite sintering furnace and other environments to measureoxygen concentration

Features


• The imported new-type longevously zirconia detector is with high accuracy and a rapid response speed for features, etc.;

• N2 or O2 Display mode available;

• The auto-compensation system for temperature with high accuracy could eliminate the influence from the environment temperature;

• The accurate measurement of oxygen concentration among the range of ppm~% can be met through one-point calibration in the air;

• The size is small and easy to maintain;

• The auto-compensation system for temperature with high accuracy could eliminate

• the influence from the environment temperature.

• The upper and lower alarm limits can be set freely among the whole range

Specifications:


Parameter

Description

Model No.

OXYMON-ZPM

Measurement display

O2 or N2

Measuring Principle

Zirconia

Measuring range                                

0-10/100/1000 PPM/ 21 % (User Configurable) 

Accuracy                           

± 1.5 % FS

Repeatability

± 1.0 % FS

Operating Temperature                          

0~60° C

Ambient Temperature

-10~50° C

Sample Mode

Sample Gas In

Sample Gas flow

300~500ml/Min

Sample Gas pressure

95kpa ~105kpa

Sample In & Out port size

6mm

Response Time                                

T90 < 30 Sec

Background gas

Nitrogen and Oxygen Mixed gas

Power Supply                        

85~240 VAC,50/60Hz, 250VA

Analogue Output                   

4-20 ma Isolated ,500Ω max

Size

80x160x142mm (HxWxD)

Install Cust Out

76x151mm (HxW)

Relay output

1 Nos Potential free

Service Life

>22000 hours (Under Normal Use)

Install Mode

Frame mount or retaining clap carried by the Oxygen sensor

Paramagnetic Oxygen Analyzer
Image 1

Description


Model No: ZY-OXY-PM/PMD
The   ZY-OXY-PM   series   paramagnetic   gas   analyzer   is   based   on   the   characteristics   of   oxygen   with high paramagnetic. It can detect various concentrations of oxygen such as trace oxygen, constant oxygen and purity oxygen.  The magnetic mechanical principle has high analysis precision and long service life. It has non-explosion-proof and explosion-proof models and can be used in industrial hazard applications.

Features


• The mechanical dumbbell type paramagnetic principle has high precision, short preheating time, quick response and good linearity,

• Direct measurement of the paramagnetic properties of oxygen with low gas interference.Compared to electrochemical sensor, it adopts non-consumable components, the normal lifespan can last over 1O years.Trace, constant, purity oxygen, multi-range is optional. LCD display, concentration curve, history data and other information display.

• RS485 signal output, relay output, compatible with various control systems. Standard 19-inch chassis design(non-explosion-proof}, can be equipped with sampling system for mast of working conditions.

• Thick carbon steel casing {explosion-proof type). explosion-proof grade up to ExdllCT6, can be used in explosive hazardous areas.

• Soft boot and watchdog functions, to keep a stable work without crash.

Specifications:


Parameter

   Description

Model

ZY-OXY-PM:non-explosion proof

ZY-OXY-PMD: explosionproof

Measure range

02:0-5%/15%/30%/100oVOL

principle

Customized   paramagnetic

Accuracy

+/-0.1%VOL

Resolution

0.01%/0.1%VOLbasedontherange

repeatability

+/-0.5%

 

Zero drift

+/-0.5%FS/7d

 

Span drift

+/-0.5%FS/7d

 

Response time

<=5s(T90)

 

AIR QUALITY MONITORING ANALYZER
Image 1

Description


MODEL: SEL-AQMS-600

·    The SEL-AQMS-600 using real-time data collection for common parameters in the atmospheric environment (TVOC, carbon monoxide, sulfur dioxide, nitrogen dioxide, ozone, PM2.5, PM10), supporting 24-hour online monitoring. It adopts the current advanced high-precision four-electrode electrochemical and optical technology principles, featuring fast response, strong reliability, low maintenance cost and long service life. The data collected on-site is sent to the data aggregation cloud service platform.

·     The SEL-AQMS-600 using real-time data collection for common parameters in the atmospheric environment (TVOC, carbon monoxide, sulfur dioxide, nitrogen dioxide, ozone, PM2.5, PM10), supporting 24-hour online monitoring. It adopts the current advanced high-precision four-electrode electrochemical and optical technology principles, featuring fast response, strong reliability, low maintenance cost and long service life. The data collected on-site is sent to the data aggregation cloud service platform.

Specifications:



TDLAS based Cross Duct Analyzer
Image 1
Image 2

Description


Model: UT-IN Series  

The laser gas analyzer can measure high-temperature (700°C), high-dust (50g/m3) flue gas,and can realize in-situ analysis at the work site; and the laser gas analyzer has a short response time, which is a true "real-time online" analysis instrument. It can be used to measure CO, CO2, O2, NH3, HCL, HF, CH4 and other gases. Provide real-time and accurate data for process monitoring, safety monitoring, and pollution monitoring.

Features


  • ·        High Precision, Extremely Low Drift
  • ·        High selectivity, No Cross interference
  • ·        High temperature gas can be measured, up to 700 deg C
  • ·        It can measure complex gas mixture and their component changes
  • ·        No affected by dust
  • ·        Reponse time <1s
  • ·        Long maintenance period and low cost
  • ·        long service service life
  • ·        Suitable up to 50 g/m3 dust load

Applications



Specifications:


Parameter

   Description

Model No.

UT-IN Series

Measuring Principle

TDLAS (Tunable diode laser absorption spectroscopy)

Optical channel Length

<15 meter

Response time

<1 Sec

Accuracy                           

± 1 % FS

Span drift

± 1 % FS

Repeatability

± 1 % FS

Maintenance Intervals

<2 times /Year, Clean optical window (No consumables need)

Calibration Intervals

<2 times/year

Operating Temperature                          

Up to 700° C

Protection class

IP67

Wetted parts

SS316L

Area classification

Suitable for Hazardous area (Ex d IIC T5)

Analog signal

4-20mA Isolated Current output (max load 500 ohms)

Analog input                              

4-20mA Current (Temp., Pressure compensation) Optimal

Digital Output

RS485/RS232

Relay Output

3-wire output (24V ,1A)

Power Supply                        

24VDC / 110VAC~230 VAC,50/60Hz, <50W

Purge Gas                   

3 to 8 bars Industrial N2, Purification Instrument Air

Ambient Temperature

-30 ~ 65° C

Transmitter & Receiver Enclosure Material

Cast aluminum shell

Installation

Cross duct In-situ Installation

Process connection

Flange (Size Customized as per requirements)

Standard Accessories

Mounting Spool piece, Root Valve, Interconnection cable and Manual Cal. kit